Skip to main content

AVASystemsNordic

AVA SafePipe

AVA SafePipe

Any buried pipe that has a leak presents two distinct challenges: locating the actual leak point and controlling where the released liquid migrates. Many conventional leak-detection systems rely on sensors installed at selected locations along or around the pipe. But subsurface conditions can change over time, and sites may be modified or rebuilt. Once released, the liquid leaking can migrate through pathways in the surrounding soil or backfill, meaning that it may become detectable or reach the surface tens of meters from the actual leak point, potentially long after the leak originally began.

AVA SafePipe answers both. Developed by AVA Systems Nordic and in service since 2008, it builds the environmental membrane and the leak detection into the pipe wall as a single assembly. The pipe monitors itself end to end, so a leak is found and reported where it starts and is kept inside the outer jacket of the pipe.

Learn More

Arrow Right Streamline Icon: https://streamlinehq.com

Leak deteced

±1 Meter

Monitoring

24/7/365

In service

20+ Years

System construction

Inside AVA SafePipe

A Complete Solution

Pipes, sensors and environmental membranes are all commercially available separately. The difficulty is combining them so the result stays reliable, then installing the complete system on construction site, and commissioning it consistently.

SELECTED COMPONENT

Outer Jacket

The HDPE outer jacket forms the protective outer layer of AVA SafePipe. It acts as a barrier between the insulation and the surrounding environment, helping to prevent external moisture from entering the pipe assembly.

SELECTED COMPONENT

Moisture Loop

The moisture loop detects moisture entering the PUR insulation. Embedded copper wires work with the carrier pipe as a reference to monitor the insulation for water ingress. This provides an indication of moisture that requires investigation, independently of the TraceTek leak-detection system.

SELECTED COMPONENT

Cu-Pipe (Optional)

The optional copper tube provides a dedicated route for a heat-tracing cable within the pipe assembly. It is included where additional heating is required to maintain the specified operating temperature. The heating requirements are determined by the liquid being transported and the installation conditions.

SELECTED COMPONENT

Carrier Pipe

The carrier pipe transports the liquid through AVA SafePipe. Its material, diameter and operating limits are selected to suit the liquid, pressure and temperature of the application. The surrounding construction combines insulation, external protection and integrated monitoring around this central pipe.

SELECTED COMPONENT

PUR Insulation

The closed-cell polyurethane (PUR) foam insulates the carrier pipe and supports its position within the outer jacket. The insulation also accommodates the moisture loop, the perforated guide tube for the TraceTek cable and, where required, the optional copper tube for heat tracing.

SELECTED COMPONENT

TraceTek Cable

The TraceTek sensing cable detects compatible liquid that reaches it inside the perforated guide tube. Connected to suitable monitoring equipment, it triggers an alarm and helps locate the leak along the sensing route. The cable type is selected for the liquid being monitored.

Applications

Where is AVA SafePipe used?

For Demanding Applications

Leaks can be difficult to locate, particularly where pipes are buried or otherwise inaccessible. AVA SafePipe combines leak detection and insulation moisture monitoring, helping operators identify problems and direct inspection to the affected area.

SELECTED AREA

Aviation fuel pipelines

Airport fuel pipelines often run underground or beneath operational areas, where inspection is difficult. AVA SafePipe integrates leak detection into the pipe construction, helping operators locate leaks and direct inspection to the affected section.

SELECTED AREA

Fuel transfer at ports

Fuel transfer pipelines connect quayside loading points with storage and distribution facilities. AVA SafePipe helps operators locate leaks along these routes, providing information to guide inspection where a release could affect surrounding land and water.

SELECTED AREA

Pipelines within industrial facilities

Industrial pipelines connect storage tanks, production equipment and utilities. AVA SafePipe combines liquid leak detection with monitoring of moisture in the insulation, helping maintenance teams investigate alarms and assess where corrective work is needed.

SELECTED AREA

Fuel supply to critical equipment

Power generation plant and backup equipment depend on reliable fuel supply pipelines. AVA SafePipe helps operators locate fuel leaks along the supply route, while a separate moisture circuit monitors water ingress into the insulation.

SELECTED AREA

Storage and transfer pipelines

Fuel storage sites depend on transfer pipelines between tanks, loading points and equipment. AVA SafePipe monitors these connections, helping operators locate leaks beyond the tank itself and direct maintenance to the affected part of the pipeline.